The Schiller Tranquility Vital Signs Patient Monitor offers Patient Monitoring with a simple interface, in a lightweight, portable, battery-powered package.
Features and Benefits
- Weighing in at less than 3 Lbs.
- Well suited for any patient care area by offering a multitude of vital sign combinations.
- Well suited for both bed side and mobile spot check use.
- Simplifies clinician use by incorporating a touch screen with a simple user interface making the Tranquility VS intuitive for any user.
- Great for neonatal, pediatric and adult patients.
- Included SpO2 only.
Note: The NIBP parameter is available; accessories are sold separately.
Materials Included
- Tranquility VS Monitor
- 1 SpO2 Sensor Cable
- 1 SpO2 Adult Reusable Finger Sensor
- 1 Lithium Ion Battery
- 1 Power Cord
- User Manual
Technical Specifications
- Physical Dimensions & Weight
- Base Unit
- Height: 8"
- Width: 4.5"
- Depth: 4"
- Weight: 2.5 lbs
- Base Unit
- Performance Specifications
- Display: 5" (Diagonal) Color TFT
- Resolution: 800 x 3 (RGB) x 480
- Indicator:
- Alarm Indicator
- Power Indicator
- Pulse beep and alarm sound
- Trend time: From 1 to 72 hours
- NIBP (Optional)
- Measuring Technology: Automatic oscillating measurement
- Cuff Inflating: < 30s (0 ~ 300 mmH, standard adult cuff)
- Measuring Period: AVE < 40s
- Mode: Manual, Auto, STAT
- Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
- Pulse Rate Range: 30 bpm ~ 250 bpm
- Measuring Range:
- Adult/Pediatric Mode
- SYS: 40 ~ 250 (mmHg)
- DIA: 15 ~ 200 (mmHg)
- Neonatal Mode
- SYS: 40 ~ 135 (mmHg)
- DIA: 15 ~ 100 (mmHg)
- Adult/Pediatric Mode
- Resolution: 1mmHg
- Pressure Accuracy: Maximum Mean error: ± 5mmHg
- Maximum Standard Deviation: 8mmHg
- Overpressure Protection:
- Adult Mode: 280 (mmHg)
- Neonatal Mode: 150 (mmHg)
- Alarm Limit:
- SYS: 50 ~ 240 mmHg
- DIA: 15 ~ 180 mmHg
- Standards: Meets performance standards of ANSI/AAMI SP10:2002
- SpO2:
- ASpO2: Anti-motion SpO2
- SpO2 % Range: 0~100%
- SpO2 Accuracy:
- ±2% (70 ~ 100%,non-motion)
- ±3% (70 ~ 100%, motion)
- Pulse Rate Range: 30-250 bpm
- Pulse Rate Accuracy:
- ±2 bpm (non-motion)
- ±3 bpm (motion)
- Alarm Upper-Lower Limit:
- Upper Limit: 70 ~ 100%
- Lower Limit: 70 ~ 100%
- SpO2 Probe:
- Red Light LED Wavelength: 660nm ± 5nm
- Infrared Light LED Wavelength: 940nm ±10nm
- Standards: Meets performance standards of EN ISO 9919:2005
- Networking
- Wired Networking
- Industry standard: 802.11 b/g wired network
- Frequency Range: 2.412 ~ 2.484 GHz
- Connected bedside number: Up to 16 bedside monitors
- Wireless Networking
- Up to 100 m indoors
- Industry standard 802.11 b/g wireless
- Supports TCP/IP and UDP/IP Protocols
- Wired Networking
- Power
- Source: External AC power or internal battery
- AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
- Battery: Built-in and lithium Ion rechargeable, 12.6V/5Ah
- Charge Time: 8 Hours
- Operating Time: 3 Hours
- Environmental Specifications
- Temperature:
- Operating: 5 ~ 40 °C
- Storage: -10 ~ 45 °C
- Humidity Range
- Operating: : ≤80 %
- Storage: ≤80 %
- Fuse: 3.15A/250V
- LCD Specifications
- Display Type: TFT Color LCD
- Size (Diagonal): 5"
- Active Area:
- Width: 152.4 mm
- Height: 91.44
- Color Arrangement: RGB-Stripe
- Dot Pitch
- Width: 0.0635
- Height: 0.1905
- Display Mode: Normally White, Transmissive
- Interface: Digital (TTL)
- Surface Treatment: Anti-Glare
- Touchscreen Specifications
- Type: Four Wire Analog Resistive Touch Panel
- Input Mode: Stylus Pen or Finger
- Connector: FPC
- Insulation Resistance: 25MΩ
- Voltage: 7VDC
- Chattering: 10 ms
- Transparency: 80%
- Surface Hardness: 3H
- Durability-Surfacing Scratching: Write 100,000
- Active Force: 80 gf
- Knock Test: 1,000,000 times
Warranty Information
- 18-Month Warranty