Schiller Tranquility VS Vital Signs Monitor w/ SpO2, NIBP and Temperature

Schiller

(No reviews yet) Write a Review
SKU:
2.987652
Weight:
3.00 LBS
$1,855.66
MSRP: $2,061.84
(You save $206.18 )
For More Affordable Finance Options Click - Here

The Schiller Tranquility Vital Signs Patient Monitor offers Patient Monitoring with a simple interface, in a lightweight, portable, battery-powered package.

Features and Benefits

  • Weighing in at less than 3 Lbs.
  • Well suited for any patient care area by offering a multitude of vital sign combinations.
  • Well suited for both bed side and mobile spot check use.
  • Simplifies clinician use by incorporating a touch screen with a simple user interface making the Tranquility VS intuitive for any user.
  • Great for neonatal, pediatric and adult patients.
  • Included SpO2, NIBP and Covidien Filac 3000 EZ Thermometer (Thermometer does not interface with the Schiller Tranquility VS monitor, readings are separate)


Materials Included

  • Tranquility VS Monitor
  • 1 SpO2 Sensor Cable
  • 1 SpO2 Adult Reusable Finger Sensor
  • 1 Adult Blood Pressure Cuff
  • 1 Covidien Filac 2000 Thermometer
  • 1 Probe Cover
  • 1 Lithium Ion Battery
  • 1 Power Cord
  • User Manual

Technical Specifications

  • Physical Dimensions & Weight
    • Base Unit
      • Height: 8"
      • Width: 4.5"
      • Depth: 4"
    • Weight: 2.5 lbs
  • Performance Specifications
    • Display: 5" (Diagonal) Color TFT
    • Resolution: 800 x 3 (RGB) x 480
    • Indicator:
      • Alarm Indicator
      • Power Indicator
      • Pulse beep and alarm sound
    • Trend time: From 1 to 72 hours
  • NIBP
    • Measuring Technology: Automatic oscillating measurement
    • Cuff Inflating: < 30s (0 ~ 300 mmH, standard adult cuff)
    • Measuring Period: AVE < 40s
    • Mode: Manual, Auto, STAT
    • Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
    • Pulse Rate Range: 30 bpm ~ 250 bpm
    • Measuring Range:
      • Adult/Pediatric Mode
        • SYS: 40 ~ 250 (mmHg)
        • DIA: 15 ~ 200 (mmHg)
      • Neonatal Mode
        • SYS: 40 ~ 135 (mmHg)
        • DIA: 15 ~ 100 (mmHg)
    • Resolution: 1mmHg
    • Pressure Accuracy: Maximum Mean error: ± 5mmHg
    • Maximum Standard Deviation: 8mmHg
    • Overpressure Protection:
      • Adult Mode: 280 (mmHg)
      • Neonatal Mode: 150 (mmHg)
    • Alarm Limit:
      • SYS: 50 ~ 240 mmHg
      • DIA: 15 ~ 180 mmHg
    • Standards: Meets performance standards of ANSI/AAMI SP10:2002
  • SpO2:
    • ASpO2: Anti-motion SpO2
    • SpO2 % Range: 0~100%
    • SpO2 Accuracy:
      • ±2% (70 ~ 100%,non-motion)
      • ±3% (70 ~ 100%, motion)
    • Pulse Rate Range: 30-250 bpm
    • Pulse Rate Accuracy:
      • ±2 bpm (non-motion)
      • ±3 bpm (motion)
    • Alarm Upper-Lower Limit:
      • Upper Limit: 70 ~ 100%
      • Lower Limit: 70 ~ 100%
    • SpO2 Probe:
      • Red Light LED Wavelength: 660nm ± 5nm
      • Infrared Light LED Wavelength: 940nm ±10nm
    • Standards: Meets performance standards of EN ISO 9919:2005
  • Rapid Temperature:
    • Temperature Measurement Range: 30°C to 43°C (86°F to 109°F)
    • Measurement Times (After Insertion into Measurement Site)
      • 3-5 seconds (Non-Fever Temps)
      • 8-10 Seconds (Fever Temps)
      • Oral Standard Mode: 6-10 Seconds
      • Rectal Mode: 10-14 seconds
      • Direct Mode (All Sites): 60-120 seconds
    • Pulse Timer:
      • 60 Second count with a “beep” at 15 seconds
      • 2 “beeps” at 30 seconds
      • 1 “beep” at 45 seconds
      • 2 “beeps” at 60 seconds
    • Patient Accuracy: A Standard Prediction Mode reading and a Direct Mode reading will differ by less than ±0.2°C (±0.4°F) on 98% of tested patients
    • Batteries:
      • Four “AA” Batteries Required
      • Standard IEC package size.
      • Alkaline --1.5 Volt
      • Approx. 6000 temperature readings
    • Standards: Meets performance standards of EN 12470-3:2000, ASTM E1112:2006
  • Networking
    • Wired Networking
      • Industry standard: 802.11 b/g wired network
      • Frequency Range: 2.412 ~ 2.484 GHz
      • Connected bedside number: Up to 16 bedside monitors
    • Wireless Networking
      • Up to 100 m indoors
      • Industry standard 802.11 b/g wireless
      • Supports TCP/IP and UDP/IP Protocols
  • Power
    • Source: External AC power or internal battery
    • AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
    • Battery: Built-in and lithium Ion rechargeable, 12.6V/5Ah
    • Charge Time: 8 Hours
    • Operating Time: 3 Hours
  • Environmental Specifications
    • Temperature:
      • Operating: 5 ~ 40 °C
      • Storage: -10 ~ 45 °C
    • Humidity Range
      • Operating: : ≤80 %
      • Storage: ≤80 %
  • Fuse: 3.15A/250V
  • LCD Specifications
    • Display Type: TFT Color LCD
    • Size (Diagonal): 5"
    • Active Area:
      • Width: 152.4 mm
      • Height: 91.44
    • Color Arrangement: RGB-Stripe
    • Dot Pitch
      • Width: 0.0635
      • Height: 0.1905
    • Display Mode: Normally White, Transmissive
    • Interface: Digital (TTL)
    • Surface Treatment: Anti-Glare
  • Touchscreen Specifications
    • Type: Four Wire Analog Resistive Touch Panel
    • Input Mode: Stylus Pen or Finger
    • Connector: FPC
    • Insulation Resistance: 25MΩ
    • Voltage: 7VDC
    • Chattering: 10 ms
    • Transparency: 80%
    • Surface Hardness: 3H
    • Durability-Surfacing Scratching: Write 100,000
    • Active Force: 80 gf
    • Knock Test: 1,000,000 times

Warranty Information

  • 18-Month Warranty
18 months

RETURNS : For complete details of our return policy and process, please refer to our general return policy page. We take the responsibility to make sure your product
arrives in brand new working condition. Should your item arrive damaged, we will replace the product at no cost to you.

CANCELLATIONS: Please note that any specially ordered or custom-made products are non-cancellable once production has begun. Unfortunately, we are unable to
accept returns on such items.

AVAILABILITY NOTE: Availability of products may vary based on the manufacturer’s current stock levels.

Schiller Tranquility VS Vital Signs Monitor w/ SpO2, NIBP and Temperature

Schiller

Weight:
3.00 LBS
SKU:
2.987652
$1,855.66
MSRP: $2,061.84
(You save $206.18 )
For More Affordable Finance Options Click - Here

The Schiller Tranquility Vital Signs Patient Monitor offers Patient Monitoring with a simple interface, in a lightweight, portable, battery-powered package.

Features and Benefits

  • Weighing in at less than 3 Lbs.
  • Well suited for any patient care area by offering a multitude of vital sign combinations.
  • Well suited for both bed side and mobile spot check use.
  • Simplifies clinician use by incorporating a touch screen with a simple user interface making the Tranquility VS intuitive for any user.
  • Great for neonatal, pediatric and adult patients.
  • Included SpO2, NIBP and Covidien Filac 3000 EZ Thermometer (Thermometer does not interface with the Schiller Tranquility VS monitor, readings are separate)


Materials Included

  • Tranquility VS Monitor
  • 1 SpO2 Sensor Cable
  • 1 SpO2 Adult Reusable Finger Sensor
  • 1 Adult Blood Pressure Cuff
  • 1 Covidien Filac 2000 Thermometer
  • 1 Probe Cover
  • 1 Lithium Ion Battery
  • 1 Power Cord
  • User Manual

Technical Specifications

  • Physical Dimensions & Weight
    • Base Unit
      • Height: 8"
      • Width: 4.5"
      • Depth: 4"
    • Weight: 2.5 lbs
  • Performance Specifications
    • Display: 5" (Diagonal) Color TFT
    • Resolution: 800 x 3 (RGB) x 480
    • Indicator:
      • Alarm Indicator
      • Power Indicator
      • Pulse beep and alarm sound
    • Trend time: From 1 to 72 hours
  • NIBP
    • Measuring Technology: Automatic oscillating measurement
    • Cuff Inflating: < 30s (0 ~ 300 mmH, standard adult cuff)
    • Measuring Period: AVE < 40s
    • Mode: Manual, Auto, STAT
    • Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
    • Pulse Rate Range: 30 bpm ~ 250 bpm
    • Measuring Range:
      • Adult/Pediatric Mode
        • SYS: 40 ~ 250 (mmHg)
        • DIA: 15 ~ 200 (mmHg)
      • Neonatal Mode
        • SYS: 40 ~ 135 (mmHg)
        • DIA: 15 ~ 100 (mmHg)
    • Resolution: 1mmHg
    • Pressure Accuracy: Maximum Mean error: ± 5mmHg
    • Maximum Standard Deviation: 8mmHg
    • Overpressure Protection:
      • Adult Mode: 280 (mmHg)
      • Neonatal Mode: 150 (mmHg)
    • Alarm Limit:
      • SYS: 50 ~ 240 mmHg
      • DIA: 15 ~ 180 mmHg
    • Standards: Meets performance standards of ANSI/AAMI SP10:2002
  • SpO2:
    • ASpO2: Anti-motion SpO2
    • SpO2 % Range: 0~100%
    • SpO2 Accuracy:
      • ±2% (70 ~ 100%,non-motion)
      • ±3% (70 ~ 100%, motion)
    • Pulse Rate Range: 30-250 bpm
    • Pulse Rate Accuracy:
      • ±2 bpm (non-motion)
      • ±3 bpm (motion)
    • Alarm Upper-Lower Limit:
      • Upper Limit: 70 ~ 100%
      • Lower Limit: 70 ~ 100%
    • SpO2 Probe:
      • Red Light LED Wavelength: 660nm ± 5nm
      • Infrared Light LED Wavelength: 940nm ±10nm
    • Standards: Meets performance standards of EN ISO 9919:2005
  • Rapid Temperature:
    • Temperature Measurement Range: 30°C to 43°C (86°F to 109°F)
    • Measurement Times (After Insertion into Measurement Site)
      • 3-5 seconds (Non-Fever Temps)
      • 8-10 Seconds (Fever Temps)
      • Oral Standard Mode: 6-10 Seconds
      • Rectal Mode: 10-14 seconds
      • Direct Mode (All Sites): 60-120 seconds
    • Pulse Timer:
      • 60 Second count with a “beep” at 15 seconds
      • 2 “beeps” at 30 seconds
      • 1 “beep” at 45 seconds
      • 2 “beeps” at 60 seconds
    • Patient Accuracy: A Standard Prediction Mode reading and a Direct Mode reading will differ by less than ±0.2°C (±0.4°F) on 98% of tested patients
    • Batteries:
      • Four “AA” Batteries Required
      • Standard IEC package size.
      • Alkaline --1.5 Volt
      • Approx. 6000 temperature readings
    • Standards: Meets performance standards of EN 12470-3:2000, ASTM E1112:2006
  • Networking
    • Wired Networking
      • Industry standard: 802.11 b/g wired network
      • Frequency Range: 2.412 ~ 2.484 GHz
      • Connected bedside number: Up to 16 bedside monitors
    • Wireless Networking
      • Up to 100 m indoors
      • Industry standard 802.11 b/g wireless
      • Supports TCP/IP and UDP/IP Protocols
  • Power
    • Source: External AC power or internal battery
    • AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
    • Battery: Built-in and lithium Ion rechargeable, 12.6V/5Ah
    • Charge Time: 8 Hours
    • Operating Time: 3 Hours
  • Environmental Specifications
    • Temperature:
      • Operating: 5 ~ 40 °C
      • Storage: -10 ~ 45 °C
    • Humidity Range
      • Operating: : ≤80 %
      • Storage: ≤80 %
  • Fuse: 3.15A/250V
  • LCD Specifications
    • Display Type: TFT Color LCD
    • Size (Diagonal): 5"
    • Active Area:
      • Width: 152.4 mm
      • Height: 91.44
    • Color Arrangement: RGB-Stripe
    • Dot Pitch
      • Width: 0.0635
      • Height: 0.1905
    • Display Mode: Normally White, Transmissive
    • Interface: Digital (TTL)
    • Surface Treatment: Anti-Glare
  • Touchscreen Specifications
    • Type: Four Wire Analog Resistive Touch Panel
    • Input Mode: Stylus Pen or Finger
    • Connector: FPC
    • Insulation Resistance: 25MΩ
    • Voltage: 7VDC
    • Chattering: 10 ms
    • Transparency: 80%
    • Surface Hardness: 3H
    • Durability-Surfacing Scratching: Write 100,000
    • Active Force: 80 gf
    • Knock Test: 1,000,000 times

Warranty Information

  • 18-Month Warranty
18 months

RETURNS : For complete details of our return policy and process, please refer to our general return policy page. We take the responsibility to make sure your product
arrives in brand new working condition. Should your item arrive damaged, we will replace the product at no cost to you.

CANCELLATIONS: Please note that any specially ordered or custom-made products are non-cancellable once production has begun. Unfortunately, we are unable to
accept returns on such items.

AVAILABILITY NOTE: Availability of products may vary based on the manufacturer’s current stock levels.