The Nellcor Bedside SpO2 Patient Monitoring System, PM100N, provides at-a-glance access to real-time patient respiratory status information including continuous SpO2 and pulse rate monitoring and trending data.
The Nellcor™ bedside SpO2 patient monitor with home care and sleep study mode provides at-a-glance access to real-time patient respiratory status information including continuous SpO2 and pulse rate monitoring and trending data.
With home care and sleep study modes, the Nellcor™ bedside SpO2 patient monitor has functionality for non-hospital settings. The system has password protection to ensure safe use by non-clinical users, and the ability to conveniently download data for further data analysis.
The monitor includes Nellcor™ SatSeconds™ alarm management, a clinician-controlled feature that has been shown to reduce nuisance alarms.
Features
- Displays plethysmographic waveforms, pulse amplitude, and real-time SpO2 and pulse rate data
- 96-hour trend memory with data captured every four seconds for quick review of changes in patient status
- Includes SatSeconds™ alarm management, a clinician-controlled feature that has been proven to reduce nuisance alarms1
- Password protected home care and sleep study modes
- The device meets IEC 60601-1-11 for home health equipment to promote the safe and effective use of the monitor by lay users in the non-hospital setting
Specifications
| Performance — measurement range | |
| SpO2 | 1% to 100% |
| Pulse rate | 20 to 250 beats per minute (bpm) |
| Pulse amplitude | 0.03% to 20% |
| Measurement accuracy — saturation | |
| Adult | 70% to 100% ± 2 digits |
| Adult and neonate low sat | 60% to 80% ± 3 digits |
| Neonate | 70% to 100% ± 2 digits |
| Low perfusion | 70% to 100% ± 2 digits |
| Adult and neonate with motion | 70% to 100% ± 3 digits |
| Pulse rate | |
| Adult and neonate | 20 to 250 bpm ± 3 digits |
| Low perfusion | 20 to 250 bpm ± 3 digits |
| Adult and neonate with motion | 20 to 250 bpm ± 5 digits |
| Electrical — instrument | |
| Power requirements | 100 to 240 VAC, 50/60 Hz, 45 VA |
| Fuse rating | Fast-acting 2A 32VAC/DC, Fast-acting 500mA 32VAC/50DC |
| Electrical — battery | |
| Type | Lithium ion |
| Battery capacity | Minimum of eight hours using new, fully charged battery with no alarms; optional 16-hour battery available. |
| Environmental — temperature | |
| Operating conditions | 5 C to 40 C (41 F to 104 F) |
| Transport and storage (in shipping carton) | -20 C to 60 C (-4 F to 140 F) |
| Environmental — humidity | |
| Operating conditions | 15% to 93% noncondesending |
| Transport and storage (in shipping carton) | 15% to 93% noncondesending |
| Environmental — altitude | |
| Operating conditions | -170 m to 4,877 m (-557 ft to 16,000 ft) |
| Transport and storage (in shipping carton) | -304 m to 6,096 m (-1,000 ft to 20,000 ft) |
| Physical characteristics | |
| Weight | 1.6 kg (3.5 lbs including battery) |
| Size | 82 H × 255 W × 155 D (mm), (3.23 H ×10.04 W × 6.10 D (in)) |
| Equipment classifications | |
| Type of protection against electric shock | Class 2 (internally powered) |
| Degree of protection against electric shock | Type BF — applied part |
| Mode of operation | Continuous |
| Liquid ingress | IP 22 |
| Output | |
| Trend data download via wired or USB for archiving or data analysis | |
| Display/indicators | |
| Pulse amplitude indicator (eight segments) | |
| Visual indicators | Pulse search, audible alarms silenced or off, interference indicator, battery charging, and SatSeconds alarm management clock, pleth wave form |
| Alarms | |
| SatSeconds alarm management | |
| Audible and visual alarms for high/low saturation and pulse rate, low battery, sensor off, and sensor disconnect | |
| Categories | Patient status and system status |
| Priorities | Low, medium and high |
| Notification | Audible and visual |
| Setting | Default, institutional, and last setting |
| Alarm system delay | < 10 seconds |
| Optional accessories | |
|
|
| Available modes | |
|
|
| Connectivity | |
|
|
| Simple setup and maintenance | |
| The Nellcor™ bedside SpO2 patient monitoring system is RoHs compliant, and enables hospital staff to set institutional defaults, replace the battery, perform diagnostics to troubleshoot performance issues, and perform on‑site maintenance on the monitor. | |
RETURNS :
For complete details of our return policy and process, please refer to our general return policy page. We take the responsibility to make sure your product
arrives in brand new working condition. Should your item arrive damaged, we will replace the product at no cost to you.
CANCELLATIONS: Please note that any specially ordered or custom-made products are non-cancellable once production has begun. Unfortunately, we are unable to
accept returns on such items.
AVAILABILITY NOTE: Availability of products may vary based on the manufacturer’s current stock levels.