Criticare’s eQuality™ 506DN is the monitor for everyone. An affordable monitor with features for both spot check and continuous monitoring. The 506DN patient monitor with sturdy carry-handle attaches quickly to a rolling stand. It can operate on battery power or directly from AC power. It is lightweight and designed for ease of use as a mobile monitor. With a compact design, the 506DN patient monitor adapts readily to hospital, clinic and transport requirements.
Features and Benefits
- Proprietary ComfortCuff® NIBP measures on inflation for faster, more comfortable readings.
- Criticare DOX™ digital SpO2 technology with waveform display.
- Audible and visual alarms are adjustable for use in continuous monitoring.
- Large responsive keys for fast spot checking with an easy to clean membrane keypad.
- On-screen menu selection for ease of setup and use.
- Adult, pediatric and neonate settings for a complete range of patients.
- Nurse call and connectivity to network systems.
- Trend last 24 blood pressure measurements with heart rate and SpO2.
- Rechargeable battery with direct AC power
- Optional integrated Bluetooth with printer available.
Materials Included
- eQuality Patient Monitor Unit
- (1) SpO2 Adult Sensor
- (1) NIBP Hose
- (1) Child/Small Adult NIBP Cuff
- (1) Adult NIBP Cuff
- (1) Large Adult NIBP Cuff
- (1) Rechargeable Battery
- (1) Power Cord
- (1) External Printer
- (1) 1 Paper Roll
- User Manual
Note: The CAT-533 Printer Paper is used for Non-Bluetooth version (506DN) and the CAT-2231 Printer Paper is used for Bluetooth & Printer version (506DNB)
Physical Properties
- Mechanical Weight: 4.5 lbs; 2 kg
- Size: 8 in (H) x 5.5 in (W) x 5.75 in (D); 20.3 cm (H) x 14 cm (W) x 14.6 cm (D)
Non-Invasive Blood Pressure
- Technique: Oscillometric measure upon inflation
- Measurement Time: <40 seconds typical; 0 to 300mmHg; standard adult cuff
- Automatic Measurement
- Cycles: 1 - 60 minute; 2 - 4 hour; STAT
- Inflation Pressure Range: 30 to 300mmHg (Adult)
- 30 to 150mmHg (Pediatric)
- 20 to 150mmHg (Neonate)
- Resolution: 1mmHg
- Clinical Accuracy: SP-10:2002
- Transducer Accuracy: ±2mmHg or ±2% of reading, whichever is greater, over full range
- STAT mode: 5 minutes of consecutive readings
Pulse Oximetry
- Range: 1% to 99%
- Resolution: 1%
- Accuracy: 70% to 99% range: ±2%;
- 50% to 69% range: ±3%;
- <50%: unspecified
- Method: Dual wavelength LED
- Audio: Tone with each detected pulse; pitch varies with saturation
Heart (Pulse) Rate
- Range: 20 to 300bpm
- Accuracy: Greater of ±1bpm or ±1%, of reading
- Unspecified for <30 or >240 bpm
- Resolution: 1bpm Pulse
- Volume: 10 levels or Off
Alarms
- Indication: Audible; Visual
- Volume: 10 levels or Off
- Silence: Yes; 2 minutes or permanent
Trend Memory
- Memory: Last 24 NIBP measurements
- Parameters: Systolic, Diastolic, MAP, Pulse Rate (records SpO2 pulse rate and SpO2 saturation if oximtery is monitored)
Displays
- Type: Monochrome LCD
- Parameters: NIBP, SpO2, pulse rate plethysmograph
- Status: Alarm Silence; Sensor; Low Battery; External Power; Patient Size
- Languages: English and Spanish
System Output
- Nurse Call: Contact switch; 3.5 mm phone jack
- Com Port: Serial, RS 232-compatible
- Settings: External printer or CUSP
Power Requirements
- Voltage: 100 to 240 VAC, 50 to 60 Hz
- Battery: Rechargeable
- Battery Life: 8 hours typical
- Recharge Time: 6 hours
Environmental
- Operating Temperature: 32º to 104º F; 0º to 40º C
- Storage Temperature: –4º to 149º F; -–20º to 65º C
- Operating Humidity: 5% to 95%, non-condensing Classification Type of Protection: Class I equipment
- Degree of Protection: Type CF defibrillator-proof equipment
- Protection against Ingress: IPX1 rating, Drip-Proof Equipment
Office Management Software Compatibility - CSI products are compatible with the following OMS products below.
- Kodak WINOMS CS by Carestream Dental LLC
- TiME for OMS by Decision Base, Inc.
- U.S. HealthRecord powered by TeamLINKS, Inc.
- Oral Surgery-Exec® by DSN Practice Management Software
- OMSVision® by HenrySchein Practice Software
- Windent® by Carestream Dental LLC
- ProVation® Medical
- gMed
- Endosoft®
Warranty Information
- 2-Year Warranty
RETURNS :
For complete details of our return policy and process, please refer to our general return policy page. We take the responsibility to make sure your product
arrives in brand new working condition. Should your item arrive damaged, we will replace the product at no cost to you.
CANCELLATIONS: Please note that any specially ordered or custom-made products are non-cancellable once production has begun. Unfortunately, we are unable to
accept returns on such items.
AVAILABILITY NOTE: Availability of products may vary based on the manufacturer’s current stock levels.