Welch Allyn Diagnostic Cardiology Suite PC-Based Spirometer

Welch Allyn

(No reviews yet) Write a Review
SKU:
DCSS-NXX
Weight:
15.00 LBS
$2,325.60
Adding to cart… The item has been added

On-Site Training Included! 

The diagnostic cardiology suite with spirometry is a PC-based spirometry platform that helps caregivers enhance patient outcomes and staff efficiency by delivering clinical accuracy, superior service, and seamless connectivity.

Diagnostic Cardiology
Suite - Demo
Diagnostic Cardiology Suite
& AllScripts TouchWorks
EHR - Spirometry Workflow
Diagnostic Cardiology Suite
& AllScripts Professional
EHR - Spirometry Testing

 

Features and Benefits
  • Integrated ambient sensors enter temperature, pressure or humidity values before an exam, so you don’t have to
  • Help perform exams correctly, the first time, with an incentive screen.
  • Instantly verify the quality and variability of each test's performance.
  • Bidirectional connectivity with leading EMR's
  • Easily access prior exams to monitor treatment plans and asses patient improvement overtime
  • Uses disposable, single-use transducers to help reduce the risk of cross contamination between exams.
  • Securely control user logins, assign user roles and access audit trails
  • Save PDFs to any network folder
  • Available with or without syringe
Materials Included
  • PC-based Spirometery
  • (1) Spirometry Software on USB
  • (1) Pressure Tubing
  • (4) Disposable Flow Transducers
  • (1) Calibration Syringe (Optional)
  • User Manual
CPT Code

  • 94010 - Spirometry, including graphic record, total and timed vital capacity, expiratory flow rate measurement(s), with or without maximal voluntary ventilation; National Average Reimbursement: $36.72
  • 94060 - Bronchodilation responsiveness, spirometry as in 94010, pre- and post-bronchodilator administration; National Average Reimbursement: $57.75

Technical Specifications
  • Test Types: Supported FVC, SCV, MVV, Pre- and Post-bronchodilation
  • Sensor Type: Pneumotach
  • Accuracy & Reproducibility: Compliant with ATS/ERS 2005 Guidelines and ISO 26782 Guidelines
  • Flow Range: +/- 14 L/sec
  • Volume Range: 0-14 L
  • Resistance: Compliant with ATS/ERS 2005 Guideline and ISO 26782 Guidelines (Impedance does not exceed 0.15kPa/(L/s) with flows up to 14 L/s)
  • Interpretation
    • 1991 ATS Interpretation Standards
    • Lung Age calculation available
    • Automatic Interpretation available
    • User-defined interpretation statements available
  • Parameters
    • FVC, FIVC, FIV1, FIV1%, FEV0.5, FEV1, FEV2, FEV3, FEV5, FEV6, FEV0.5, FEV0.5%, FEV1%, FEV1/FVC, FEV2%, FEV3%, FEV5%, FEV6%, PEF, FEF25, FEF50, FEF75, FEF0.2-1.2, FEF25- 75, FEF75-85, PIF, FIF50, FEF50/FIF50, FEV1/FEV6, FET, MEF25, MEF50, MEF75 SVC, ERV, IRV, VT, IC, BF, MV, Tin, Tex, Tin/Tex MVV, MV, VT, BF, DFRC
  • Quality Checks
    • ATS Acceptability and ATS Reproducibility
    • Effort-quality messages
    • Audio and visual incentive for coaching patients
  • Processor: Performance equivalent to an Intel Xeon® class, quad-core with hyperthreading
  • Resolution: 1024 x 768 or better
  • RAM: Minimum 4 GB
  • Operating System
    • Microsoft Windows 2012 R2 (64-bit)
    • Microsoft Windows 2016
  • System Disk: 100 GB for OS and product installation (RAID recommended for data redundancy)
  • Data Disks: 550 GB hard drive space available HD controller with 128 MB read/write cache (RAID recommended for data redundancy)
Warranty Information
  • 1-Year Warranty